Independent Laboratory Test Results
At Mycolife, quality is not only stated it is verified.
We have begun publishing independent laboratory test results for selected Mycolife products and production batches. Our aim is to provide customers, healthcare professionals and business partners with clear, accessible and verifiable information about the quality and purity of our organic liquid mushroom extracts.
This page contains a summary of the results together with the complete laboratory reports in PDF format.
The results shown on this page relate specifically to the product and production batch identified below. They should not be interpreted as laboratory results for every previous or future production batch.
Product: Mycolife FORTE Hericium erinaceus
Product type: Organic liquid mushroom extract
Production batch: 220626
Sample received by the laboratory: 8 July 2026
Laboratory reports issued: 22 July 2026
Company: Mycolife Italia SRLS, Rome, Italy
“Not detected” means that the substance was not detected at or above the limit of quantification stated in the laboratory report. It does not necessarily mean that the absolute concentration is zero.
CFU/g means colony-forming units per gram and is used to express microbiological counts.
The microbiological analysis included general microbial indicators as well as selected hygiene and food safety parameters.
Results:
• Total aerobic microbial count at 30°C: 3,500 CFU/g
• Yeasts and moulds: less than 10 CFU/g
• Escherichia coli: less than 10 CFU/g
• Salmonella spp.: not detected in 25 g
• Coagulase-positive staphylococci: less than 10 CFU/g
• Enterobacteriaceae: less than 10 CFU/g
Download the complete microbiological report
The product was tested for selected mycotoxins associated with fungal and agricultural raw materials.
Results:
• Aflatoxin B1: not detected
Limit of quantification: 0.1 µg/kg
• Total aflatoxins B1, B2, G1 and G2: not detected
Limit of quantification: 0.4 µg/kg
• Ochratoxin A: not detected
Limit of quantification: 0.5 µg/kg
Download the complete mycotoxin report
The product was analysed for selected metals.
Results:
• Lead: not detected
Limit of quantification: 0.02 mg/kg
• Cadmium: not detected
Limit of quantification: 0.01 mg/kg
• Nickel: not detected
• Mercury: 0.03 mg/kg
• Arsenic: 0.01 mg/kg
• Chromium: 0.05 mg/kg
Download the complete metals report
A detailed multi-residue pesticide screening was performed on the product.
The pesticide residues included in the analytical panel were not detected at or above the respective limits of quantification stated in the report. For most of the listed substances, the limit of quantification was 0.005 mg/kg.
The complete detailed report contains the individual substances, analytical methods and results.
Download the detailed pesticide residue panel
Our commitment to transparency
Publishing laboratory results is part of Mycolife’s commitment to quality, traceability and transparent communication.
As additional products and production batches are analysed, this page will be expanded with new laboratory reports and updated information.
Mycolife Trametes versicolor
Batch 070426 – independent metals analysis
Product: Organic Trametes versicolor (Turkey Tail) mushroom extract
Production batch: 070426
Sample collected: 20 May 2026
Laboratory report issued: 5 June 2026
Report number: 26/04128
Sampling location: Mycolife Italia SRLS, Rome, Italy
Results:
• Lead: not detected
Limit of quantification: 0.02 mg/kg
• Cadmium: not detected
Limit of quantification: 0.01 mg/kg
• Mercury: 0.01 mg/kg
• Arsenic: 0.01 mg/kg
“Not detected” means that the substance was not detected at or above the limit of quantification stated in the laboratory report. It does not necessarily mean that the absolute concentration is zero.
The complete, unaltered laboratory report is available below in PDF format.
Download the complete metals report
Mycolife Reishi FORTE
Product: Mycolife Reishi FORTE
Species: Ganoderma lucidum
Product type: Liquid mushroom extract
Production batch: 230626
Testing period: 30 June – 13 July 2026
A sample of Mycolife Reishi FORTE was analysed for selected metals, polycyclic aromatic hydrocarbons and microbiological parameters.
The results below relate specifically to production batch 230626 and to the tested sample.
Results:
• Lead: less than 0.5 mg/kg
Below the laboratory quantification limit
• Cadmium: less than 0.1 mg/kg
Below the laboratory quantification limit
• Mercury: less than 0.005 mg/kg
Below the laboratory quantification limit
• Arsenic: less than 0.5 mg/kg
Below the laboratory quantification limit
The product was screened for selected polycyclic aromatic hydrocarbons.
Results:
• Benz(a)anthracene: less than 0.5 µg/kg
Below the laboratory quantification limit
• Chrysene: less than 0.5 µg/kg
Below the laboratory quantification limit
• Benzo(b)fluoranthene: less than 0.5 µg/kg
Below the laboratory quantification limit
• Benzo(a)pyrene: less than 0.5 µg/kg
Below the laboratory quantification limit
Results:
• Osmophilic yeasts at 25°C: less than 10 CFU/g
• Xerophilic moulds at 25°C: less than 10 CFU/g
• Enterobacteriaceae at 37°C: less than 10 CFU/g
• Escherichia coli at 44°C: less than 10 CFU/g
• Coagulase-positive Staphylococcus at 37°C: less than 10 CFU/g
• Salmonella spp.: not detected in 25 g
All heavy metals and PAH compounds listed above were below the laboratory quantification limits shown.
The selected microbiological parameters were either below the reported detection or quantification limits, or were not detected in the tested sample.
The symbol “<” means that the measured value was below the stated laboratory limit of quantification.
“Not detected” means that the microorganism was not detected in the quantity of sample specified.
The results relate only to the tested sample and production batch 230626.